    Volumetric Karl Fischer Titration

    ² Support KF Titration Mode and Titer Detection Mode.

    ² Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.

    ² Automatic/manual background drift correction ensures accurate results.

    ² Selectable units including mg, mg/L, %, ppm, etc.

    ² Settable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc.

    ² Store up to 200 titration data sets (GLP-compliant).

     

    Coulometric Karl Fischer Titration

    ² Generator cell with diaphragm.

    ² Automatic/manual background drift correction ensures accurate results.

    ² Selectable units including μg、mg、%、ppm、mg/L、μg/mL, etc.

    ² Settable parameters, including measurement unit, polarization current, stirring rate, generator current, endpoint potential, stop criterion and etc.

    ² Store up to 200 titration data sets (GLP-compliant).

     

    GENERAL FEATURES

    ² LCD display screen.

    ² Titration methods, curves and results are displayed in detail.

    ² Volumetric KF Titration and Coulometric KF Titration are supported.

    ² Data analysis feature helps user review and compare results.

    ² Data can be easily transferred to printer via RS-232 communication interface.

    ² Reset feature automatically resumes all settings back to factory default options.

     

    INSTRUMENT INCLUDES

    10ml burette, volumetric titration cell (with electrodes and anti-diffusion capillary), coulometric titration cell (with electrodes)

     

     

    Model

    ZDY-504

    Volumetric Titration

    Range

     (0.1mg~250)mg,  

    Polarization Current Accuracy

    1μA±0.2μA; 50μA±10μA;

    Repeatability

    ±0.5%

    Coulometric Titration

    Range

    10μg~20mg

    Polarization Current Accuracy

    1μA±0.2μA; 50μA±10μA;

    Working Current

    1, 1.86, 5, 10μg (H2O)/S

    Accuracy

    ± (5%+3) μg

    Repeatability

    RSD of 100μg sample measurement result ≤3%

    General

    Power supply

    AC (220±22) V, (50±1) Hz

    Dimension (mm)& Weight (kg)

    340*400*400; 10

Send your message to this supplier
  • From:
  • To:
    INESA Scientific Instrument Co.,Ltd
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service