S6000Plus UHPLC

Category:Laboratory > Analytical Instrument > Chromatography
Product Name:S6000Plus UHPLC
Price(USD):Negotiable
Company:Acchrom Technologies Co., Ltd.

Basic Info
  • Factory Location: 大连

    Main Sales Markets: North America,Central/South America,Western Europe,Eastern Europe,Australasia,Asia,Middle East,Africa

  • Contract Manufacturing: CRO,CMO

  • Sample Provided: yes

    Payment Terms: L/C

    The pump system

     

    ■ Biocompatible and salt-resistant check valve design

    New ceramic check valve is more salt-resistant and can working better uder high concentration ACN.

     Binary/Quaternary mixing pump available

    Binary gradient pump and Quaternary gradient pump are available, the pump system can be flexibly configured according to the application scenario.

     

    ■ Max Pressure limitation 70MPa

    The Max pressure reaches 70MPa, which can fully adapt to the application of 2.5um particle size chromatography columns.

     

    Sample Management system

     

    Sample carryover can reach <0.003%

    Innovative inlet design to achieve long life seal and nearly zero carryover.

    Special flush flow path and flush solution, are designed to adequately flush the entire injection system.

     

    Temperature-controlled automatic sampler

    The automatic sampler temperature control system uses the peltier temperature control module to accurately stabilize the temperature of the sampler at the set value and ensure the stability of the temperature sensitive sample.

     

     

    Flow-through needle injection mode, no sample waste

    The autosampler uses a flow-through needle injection mode to avoid the problem of wasting sample, which caused by sample loop injection mode’s necessary part --- "sample overfill", allowing for "as much injecting, as much sampling".

     

    column management system

     

    Peltier heating / refrigeration, temperature control is more stable

    Temperature setting range: 1~90℃ (minimum unit is 1℃).

    A 300-mm column can be placed

     

    Passive preheating function

    The mobile phase is pre-heated before entering the column, which reduces the interference to the temperature environment in the column and ensures excellent peak shape symmetry and sharpness and reproducibility.

     

    Rich variety of excellent performance detector

    ■A variety of detectors, to meet the different needs of users

     

    Specifications

     

    Mixing Mode:

    Binary/Quaternary

    FLow rate range:

    0.001-10.000 ml/min

    Max operate pressure:

    70MPa

    Max Injection volume:

    30ul,can be expended to 100ul

    Temp. Range:

    1-45℃ (Room Temp.-24℃-- Room Temp. +20℃)

    Injector Capacity:

    120  2ml vials, 96-well plates compatible

    Column Oven Temp:

    1-90℃(Room Temp. -24℃--Room Temp. +65℃)

    Column Switch:

    Optional

    Max Column Capacity:

    300mm column, 3 columns

    DAD detector

    1024 diodes

    Wavelength Cal:

    Built-in Hg lamp calibrate

    Max Sampling rate:

    160Hz

    Reference Wavelength:

    Independent mode, different reference wavelength can be set for each channel

Send your message to this supplier
  • From:
  • To:
    Acchrom Technologies Co., Ltd.
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service