In This Store
Category:Laboratory > Analytical Instrument > Chromatography
Product Name:S6000 HPLC
Price(USD):Negotiable
Company:Acchrom Technologies Co., Ltd.
Factory Location: Dalian
Main Sales Markets: North America,Central/South America,Western Europe,Eastern Europe,Australasia,Asia,Middle East,Africa
Contract Manufacturing: CRO,CMO
Sample Provided: yes
Payment Terms: L/C
Based on the needs of users, Acchrom Tech analyzed the development process of liquid chromatography in the past 30 years, and built the S6000 HPLC system based on the self-developed patented technology and creative modular design ideas.
Pump System
■ Double ball series check valve
Pressure is more stable and the solvent is tolerated better.
■ HFM high-frequency mixing mode
Improve the mixing accuracy of the mobile phase by increasing the proportional valve switching frequency.
The solvent is fully mixed without bigger mixer, which greatly reduces the system volume (<700ul) and improves the baseline noise caused by poor mixing.
■ High-speed feedback, real-time control & special cam curve design
Through the pressure monitoring of the system in real time, adjust the motor speed, equipped with the special curve cam drive, to ensure the stable flow, and effectively reduce the infusion pulsation. Stable flow pumping of 0.001-10.000 ml/min.
Sample Management System
■ Sample carryover can reach <0.003%
Innovative inlet design to achieve long life seal and nearly zero dead volume.
Special flush flow path and rinse fluid to adequately flush the entire injection system.
■ Temperature-controlled automatic sampler
The temperature control uses the automatic injection sample detector temperature control module to realize the effective temperature control of 1℃ ~45℃. The temperature of the sampler can be accurately stabilized at the set value to ensure the stability of the temperature-sensitive samples.
Column Management System
■ creative high-capacity design
A 300-mm column can be placed
Built-in column switching valve or functional valve is optional
■ Heating / cooling mode: Peltier
Temperature setting range: 1~90℃
Heating / cooling bidirectional capability by powerful Peltier, temperature control is faster, more accurate, more stable.
■ Mobile Phase preheating function
The mobile phase is pre-heated before entering the column, which reduces the interference to the temperature environment in the column and ensures excellent peak shape symmetry and sharpness and reproducibility.
Rich Variety of Excellent Performance Detector
■ A variety of detectors are available
Provide complete detection techniques including UV, DAD, FLR, RI, ELS detectors.
Specifications
Mixing Mode: |
Quaternary |
FLow rate range: |
0.001-10.000 ml/min |
Max operate pressure: |
45MPa / 62MPa |
Max Injection volume: |
100ul,can be expended to 1000ul |
Temp. Range: |
1-45℃ (Room Temp.-24℃-- Room Temp. +20℃) |
Injector Capacity: |
120 2ml vials, 96-well plates compatible |
Column Oven Temp.: |
1-90℃(Room Temp. -24℃--Room Temp. +65℃) |
Column Switch: |
Optional |
Max Column Capacity: |
300mm column, 3 columns |
DAD detector |
1024 diodes |
Wavelength Cal. |
Built-in Hg lamp calibrate |
Max Sampling rate: |
160Hz |
Reference Wavelength: |
Independent mode, different reference wavelength can be set for each channel |
Contact Us