    Based on the needs of users, Acchrom Tech analyzed the development process of liquid chromatography in the past 30 years, and built the S6000 HPLC system based on the self-developed patented technology and creative modular design ideas.

     

    Pump System

     

    Double ball series check valve

    Pressure is more stable and the solvent is tolerated better.

    HFM high-frequency mixing mode

     Improve the mixing accuracy of the mobile phase by increasing the proportional valve switching frequency.

    The solvent is fully mixed without bigger mixer, which greatly reduces the system volume (<700ul) and improves the baseline noise caused by poor mixing.

    High-speed feedback, real-time control & special cam curve design

    Through the pressure monitoring of the system in real time, adjust the motor speed, equipped with the special curve cam drive, to ensure the stable flow, and effectively reduce the infusion pulsation. Stable flow pumping of 0.001-10.000 ml/min.

     

     

    Sample Management System

     

    Sample carryover can reach <0.003%

     Innovative inlet design to achieve long life seal and nearly zero dead volume.

    Special flush flow path and rinse fluid to adequately flush the entire injection system.

    Temperature-controlled automatic sampler

    The temperature control uses the automatic injection sample detector temperature control module to realize the effective temperature control of 1℃ ~45. The temperature of the sampler can be accurately stabilized at the set value to ensure the stability of the temperature-sensitive samples.

     

    Column Management System

    creative high-capacity design

    A 300-mm column can be placed

    Built-in column switching valve or functional valve is optional

    Heating / cooling mode:  Peltier

     Temperature setting range: 1~90℃

    Heating / cooling bidirectional capability by powerful Peltier, temperature control is faster, more accurate, more stable.

    Mobile Phase preheating function

    The mobile phase is pre-heated before entering the column, which reduces the interference to the temperature environment in the column and ensures excellent peak shape symmetry and sharpness and reproducibility.

     

    Rich Variety of Excellent Performance Detector

    A variety of detectors are available

    Provide complete detection techniques including UV, DAD, FLR, RI, ELS detectors.

     

     

    Specifications

     

    Mixing Mode:

    Quaternary

    FLow rate range:

    0.001-10.000 ml/min

    Max operate pressure:

    45MPa / 62MPa

    Max Injection volume:

    100ul,can be expended to 1000ul

    Temp. Range:

    1-45℃ (Room Temp.-24℃-- Room Temp. +20℃)

    Injector Capacity:

    120  2ml vials, 96-well plates compatible

    Column Oven Temp.:

    1-90℃(Room Temp. -24℃--Room Temp. +65℃)

    Column Switch:

    Optional

    Max Column Capacity:

    300mm column, 3 columns

    DAD detector

    1024 diodes

    Wavelength Cal.

    Built-in Hg lamp calibrate

    Max Sampling rate:

    160Hz

    Reference Wavelength:

    Independent mode, different reference wavelength can be set for each channel

     

Send your message to this supplier
  • From:
  • To:
    Acchrom Technologies Co., Ltd.
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service