Basic Info
  • Factory Location: Dalian

    Main Sales Markets: North America,Central/South America,Western Europe,Eastern Europe,Australasia,Asia,Middle East,Africa

  • Contract Manufacturing: CRO,CMO

  • Sample Provided: yes

    Payment Terms: L/C

    Pump high precision, low pulsation, excellent stability

     

    The pump system realizes the high precision mixing of the four-element gradient system, reduces the infusion pulsation, and ensures the accuracy of infusion and the stability of use.

     

     Special curve-shaped cam design

    Special curve cam drive plunger makes the infusion more stable and lower pulsation.

     High-speed feedback, real-time control

    Through the real-time pressure monitoring of the system, adjust the motor speed, with special, curve cam drive, and further reduce the flow stability.

     

    ■ Strcade inlet and outlet check valve design

    Series two-stage pump head infusion is adopted, and the pump head inlet and outlet valves can ensure the infusion stability to a large extent and reduce the pulsation of the pump system.

     

     

     

     

    Autosampler low residue, high precision, and excellent reproducibility

     

     

    The automatic injection system adopts innovative injection system design and advanced direct injection method, with a new fit design, lower residue, stable reproduction, and fast injection to meet the high throughput requirements.

     

     Direct injection approach with low residues

    Direct injection, as part of the flow path, ensures that all the samples enter the analysis system, avoids the waste of the samples, reduces the residue of the samples in the injection system, and ensures the reproducibility of high precision injection

     

     High-precision sample injection control

    The new high-precision syringe drive unit is used to achieve excellent injection volume reproducibility and reliability of analysis results.

     

    Column Oven

     

    The column temperature box adopts the temperature control unit and specially designed preheating function to ensure the sharp, symmetrical and reproducible chromatography peak.

     

     Air circulation + preheating mode

    The mobile phase is pre-heated before entering the column to reduce the interference to the temperature in the column.

    The air inside the column temperature box is always circulating to ensure that the ambient temperature around the column is constant;

     

     

     Vertical column temperature box design

    Vertical column temperature box can be placed into a larger column: compatible with 300mm long column, can be put up to 3 long chromatcolumns.

     

     The built-in switching valve can be configured

    Reserved built-in switching valve installation valve position to meet the requirements of column switching or multi-dimensional chromatography application.

     

     

    UV-detector

     

    The UV detector, using high-quality optical unit and optimized optical path design, can provide higher sensitivity and meet the analysis of trace and trace samples.

     Quality optical unit

    The body of the optical bench adopts the overall primary forming process to ensure the stable operation of the optical device under different temperature and humidity environments.

     Dual beam design

    Using a dual beam design, the reference beam alone can effectively improve the baseline drift due to the aging of the optical components.

     

     

    Specification:

     

    Gradient mode:

    Quaternary gradient

    Flow rate range:

    0.001-10.000 ml/min

    Maximum pressure:

    40MPa 

    Max Injection volume:

    100ul, can be extended to 1000ul

    Sampler Temperature:

    1-45℃ 

    Sampler capacity:

    120-bit 2ml vial, compatible with 96-well plates

    Column temperature box temperature:

    Room temperature +5℃-65℃

    Automatic column switching valve:

    Built-in type, optional

    Column capacity:

    Max 300mm long columns, up to 3 columns

    UV detector

    Dual beam design

    wavelength self-calibration:

    Built-in Hg lamp calibrate

    wavelength coverage:

    190nm--700nm

    Maximum sampling frequency:

    100Hz

Send your message to this supplier
  • From:
  • To:
    Acchrom Technologies Co., Ltd.
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service