In This Store
Category:Laboratory > Other Instrument > Other Laboratory Equipment / Supplies
Product Name:Refrigerated heating circulator HRS-70℃~250℃
Price(USD):0.00
Company:Wuxi Guanya Refrigeration Technology Co., Ltd. (LNEYA)
Factory Location: NO.2 Building,NO.207 Hongyun Road,New District,Wuxi,Jiangsu, China
Main Sales Markets: North America,Central/South America,Western Europe,Eastern Europe,Australasia,Asia,Middle East,Africa
Monthly Production Capacity: 100
Packaging Information: standard wooden case
Delivery Lead Time: 25 working days
Sample Provided: no
Payment Terms: TT
Description
Wide working temperature range with cooling and heating function, temperature range: -70~250℃.
-70℃~250℃
Description:
The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60℃.
The cycle is closed,there is no oil mist at high temperature and no water vapor at low temperature; Wide working temperature range of heat transfer oil; The entire circulation system without use of mechanical and electric valve.
FEATURES:
1.Wide working temperature range with cooling and heating function, temperature range: -70~280℃.
2.With 2pcs of LED display controller, can show the setting temperature & actual value, and alarm value for overtemperature.
3.Efficient fast, simple topping up liquid.
4.Ensure fast cooling at high temperature and can acheive 250℃ ~ -70℃ temperature control continuously.
5.The cycle system is closed, there is no oil mist and water vapor happend, so as to assure the lab safety and heat transfer fluid lifetime.
6.Use copeland brand compressor,circulation pump,stable performance and reliable quality.
7.Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
8.Use the same kind of heat conducting in the whole heating-cooling cycle when control heat conducting medium temperature.
9.High-lift design and meet the long-distance transportation of heat conducting medium.
Technical Parameters:
Model |
HRS-25W |
HRS-35 |
HRS-50 |
HRS-70 |
HRS-100W |
HRS-150W |
|
Temperature range ℃ |
-70℃~250℃ |
-70℃~250℃ |
-70℃~250℃ |
-70℃~250℃ |
-70℃~250℃ |
-70℃~250℃ |
|
Controller |
PID adaptive controller |
||||||
Temp. control |
Heat-conducting medium outlet temp. control |
||||||
Communication protocol |
MODBUS RTU Protocol, RS 485 Interface |
||||||
Temperature feedback |
Heat-conducting medium temperature feedback PT100 |
||||||
Temp. accuracy |
±0.5℃ |
±0.5℃ |
±0.5℃ |
±0.5℃ |
±0.5℃ |
±0.5℃ |
|
Heating power |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
Cooling capacity |
250℃ |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
100℃ |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
20℃ |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
0℃ |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
-20℃ |
2000W |
3000W |
4850W |
6000W |
8200W |
14000W |
|
-40℃ |
1300W |
1750W |
2300W |
3100W |
4000W |
8750W |
|
-60℃ |
400W |
550W |
750W |
900W |
1200W |
2800W |
|
Circulation pump |
Max20L/min 2BAR |
Max35L/min 2BAR |
Max35L/min 2BAR |
Max50L/min 2BAR |
Max50L/min 2BAR |
Max50L/min 2BAR |
|
Compressor |
Copeland |
Copeland |
Copeland |
Copeland |
Copeland |
Copeland |
|
Operation panel |
Display setting temperature and testing temperature; Touch key display |
||||||
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. |
|||||||
Closed circulation system |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. |
||||||
Refrigerant |
R-404A R23 |
R-404A R23 |
R404A R23 |
R404A R23 |
R404A R23 |
R404A R23 |
|
Connection size |
DN-15 |
DN20 |
DN20 |
DN20 |
DN20 |
DN-20 |
|
Water-cooled type W (cooling water at 20℃) |
900L/H 1.5bar~4bar |
|
|
|
3200L/H 1.5bar~4bar |
4500L/H 1.5bar~4bar |
|
Dimension |
water-cooled |
400*600*1350 |
|
|
|
700*700*1350 |
700*700*1550 |
air-cooled |
|
550*680*1450 |
620*680*1450 |
|
|
|
|
Weight |
water-cooled |
190kg |
|
|
|
370kg |
420kg |
air-cooled |
|
275kg |
320kg |
370kg |
|
|
|
Power |
AC 220V 50HZ 5.2kW (max) |
AC 380V 50HZ 8kW (max) |
AC 380V 50HZ 11kW (max) |
AC 380V 50HZ 15kW (max) |
AC 380V 50HZ 20kW (max) |
AC 380V 50HZ 28kW (max) |
|
Case material |
Cold rolled steel |
||||||
Optional |
Optional 7-inch color touch screen controller, temperature curve record, data export to excel format. |
||||||
Optional |
SUS304 case material |
||||||
Optional power |
220V 60HZ three-phase, 440V~480V 60HZ three-phase |
Contact Us
Tel: (+86) 400 610 1188
WhatsApp/Telegram/Wechat: +86 13621645194
Follow Us: