In This Store
Category:Refrigeration Equipment > Other Refrigeration Equipment
Product Name:franchiser low freezer test chamber GY-A228N
Price(USD):0.00
International
Approvals/Standards:ISO
Company:Wuxi Guanya Refrigeration Technology Co., Ltd. (LNEYA)
Factory Location: Add: No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu ,China.Zip code 214142
Main Sales Markets: North America,Central/South America,Western Europe,Eastern Europe,Australasia,Asia,Middle East,Africa
Monthly Production Capacity: 10
Packaging Information: Wooden case
Delivery Lead Time: 25
Sample Provided: yes
Payment Terms: T/T
Overview:
Microcomputer control, cascade temperature controller, digital temperature display, the regulation of unit 0.1℃, inside the temperature range -20 ℃ ~ -125 ℃ adjustable.
Multi-safety protection, more reliable operation.
France TECUMSEH compressor, Germany DANFOSS compressor, EMERSON compressor, automatic cascade refrigeration technology.
With self-diagnosis function, freezer overload protection, high pressure switches, overload relays, thermal protection device and other security functions, and fully guarantee the use of safety.
Three sealed mold layer of insulation, Extra-thick high-density polyurethane foam insulation layer, the effect of good insulation; Inline vacuum insulation panels.
Human design, more convenient and flexible.
Suitable for mechanical producing plant use.
Large condenser design, fully guaranteed plant environment cooling effect.
Wide volume ratio design, large load capacity design.
Can be set to open compressors and compressor off temperature.
Fault alarm (over-temperature alarm, sensor alarm, high alarm, overheat alarm compressor.
Delay boot protection.
So grounding components safely.
7inch touch screen display, clear display inside temperature and the desire temperature; can set the over temperature alarm and the inside temperature, fault prompt functions.
Non-standard sizes can be customized, Ultra-low temperature freezer (can be produced within -100℃ 100 cubic).
Optional equipments: PLC controller, temperature recorder etc.
Can be used in touch screen, screen frozen degumming and disassembly
Application:
It is mainly used in industrial refrigerating treatment, so that the matrix of the metal structure to generate a uniform, fine and dispersed precipitation. The precipitation of carbide will improve the abrasion resistance, friction performance and increase hardness of metal. The carbide is the ideal alternative to liquid nitrogen.
For the copper sleeve and bearings contracting, it is widely used in precise mechanical assembly. Applied to large scale equipment(cars, large engineering machineries, aircraft component, Aerospace equipment parts, Military equipment parts etc.) lower temperature test.
Technical Parameters:
Model |
GY-A228N |
GY-A250N |
GY-A2A10N |
GY-A350N |
GY-A3A10N |
GY-A550N |
GY-A5A10N |
||||||
Volume |
280L |
500L |
1000L |
500L |
1000L |
500L |
1000L |
||||||
Inner dimension |
800*600*600 |
1200*650*650 |
1550*800*750 |
1200*650*650 |
1550*800*750 |
1200*650*650 |
1550*800*750 |
||||||
Type |
(Vertical) |
||||||||||||
Capacibility carrying |
150KG |
220KG |
300KG |
220KG |
300KG |
220KG |
300KG |
||||||
Designed bearing capacity is two times of the standard one, (refrigeration system is designed according to the standard capacity, when target artifact weight is greater than the standard capacity, the cooling rate will decrease) |
|||||||||||||
Temp. range |
-120℃~20℃ |
-120℃~20℃ |
-120℃~20℃ |
-135℃~0℃ |
-135℃~0℃ |
-150℃~0℃ |
-150℃~0℃ |
||||||
Cooling capacity |
0.7kw -110℃ |
1 kw -110℃ |
2 kw -110℃ |
1kw -125℃ |
2 kw -125℃ |
1 kw -140℃ |
2kw -140℃ |
||||||
Temp. accuracy |
±2℃ |
±2℃ |
±2℃ |
±2℃ |
±2℃ |
±2℃ |
±2℃ |
||||||
Heating power |
2kw |
3kw |
5kw |
3kw |
5kw |
3kw |
5kw |
||||||
Nickel-chromium alloy electric heating heater, the controller has double safety protection, with independent temperature limiter protection. |
|||||||||||||
Cooling rate |
Ambient temperature of 25℃, no-load,(from 0℃to -110℃ about 1 .5 hour; from 0℃ to -140℃ about 2 hours, cooling rate will be a little different for ambient temperature changes. |
||||||||||||
Controller |
ASET multifunctional controller |
||||||||||||
Operation panel |
7-inch color touch screen , display set temperature, measured temperature. |
||||||||||||
Temp. record |
Temperature curve and fault record , U-disk data export, excel format. |
||||||||||||
Inside circulating air |
2100 m³/h |
2750 m³/h |
4500 m³/h |
2750 m³/h |
4500 m³/h |
2750 m³/h |
4500 m³/h |
||||||
When it is open, the internal circulation fan automatically turns off. The touch screen displays open state. |
|||||||||||||
Compressor |
Emerson Copeland , adopt cascade refrigeration technology |
||||||||||||
Intermediate heat exchanger |
KAORI Plate heat exchanger |
||||||||||||
Dry filter |
Emerson |
||||||||||||
Expansion valve |
Electronic expansion valve |
||||||||||||
Evaporator |
Copper-tube with aluminum-fin |
||||||||||||
Cooling Type |
Air-cooled with water-cooled auxiliary functions (Ensure good cooling capacity when temp. above 30℃) |
||||||||||||
Means of insulation |
Polyurethane foam insulation, thermal insulation layer 150 mm, with embedded FIR boards |
||||||||||||
Safety Protection |
Self-diagnosis function;Phase sequence phase failure protection; leakage protector; cooling unit overload protection; high and low pressure switch, overload relay, thermal protection device, high temperature protection and temperature fault protection. |
||||||||||||
Case material |
Outside is cold rolled steel painting, internal is SUS304 wire drawing board. |
||||||||||||
Refrigerant |
Mix Refrigerant from LNEYA |
||||||||||||
Dimension |
2200*1150*1150 |
2700*1200*1200 |
3100*1300*1250 |
2900*1200*1200 |
3200*1300*1250 |
3000*1200*1200 |
3300*1300*1250 |
||||||
Power 380V 50HZ |
12KW MAX |
16.5KW MAX |
20KW MAX |
18KW MAX |
25KW MAX |
23KW MAX |
30KW MAX |
||||||
Weight |
570kg |
680kg |
850kg |
750kg |
900kg |
800kg |
980kg |
||||||
Optional |
High temperature reaches 80℃ and temperature accuracy is ±0.5℃;the input power will be changed. |
||||||||||||
Optional |
Temp. accuracy ±0.5℃ |
||||||||||||
Optional |
Cooling and heating with program controlled, meet cold treatment process requirements(can set 5 programs, each program can edit 45 steps.) |
||||||||||||
Optional |
Interior door, reduce cooling capacity lost when pick small workpieces (temperature below 60℃ optional) |
||||||||||||
Optional |
Outside SUS304 wire drawing board case |
||||||||||||
Optional |
Diameter 50mm cable hole |
||||||||||||
Optional |
Electric heating vacuum glass observation window (with lighting) 200mm*300mm |
||||||||||||
Optional |
Low temperature automatic defrost (can be once per hour or use manual button to defrost), ensure it can work at low temperature for long time even the door is open and close frequently) |
As the refrigerating treatment equipment is produced specially, please provide us the following information:
1. Maximum Loading.
2. Liner Size:L/W/H
3. Full load cooling to the time of the target value.
Contact Us
Tel: (+86) 400 610 1188
WhatsApp/Telegram/Wechat: +86 13621645194
Follow Us: