Basic Info
  • Factory Location: Kyoto,Japan

    Main Sales Markets: Western Europe,Asia,Middle East

  • Sample Provided: yes

    More convenient! Easier to use!

    EMS viscometer is a new type innovative viscometer that changed the common sense of viscosity measurement in the world for the first time.
    By applying torque to the spherical probe in the sample remotely from the outside of the sample container using the force of the magnetic field, we succeeded in completely separating the sample from the device.
    We have prepared a state-of-the-art viscosity analytical technology with easy-to-use software and a spherical probe that can be selected according to sample properties, enabling application in a wide field. It is also compatible with small amount, low viscosity measurement which was difficult to measure up to now.
    This product adopts part of development results obtained as the framework of JST Japan Science and Technology Agency.
    (Patent application No.5093599, US 8,365,582 B2, Applicant name: The University of Tokyo)

    Features

    Wide Temperature Range

    Temperature range : 0 to 200℃
    Temperature stability : ±0.1℃
    Heating rate : Within 10 minutes(25℃ to 200℃)

     

    Wide Measuring Range

    Viscosity range : 0.1 to 100,000mPa・s(applied φ2.0mm spherical probe)

    The standard measuring cell covers the entire viscosity range – no need to use different types of rotors.

    Short Measuring Time

    Only 1 second is required to measure samples with a viscosity below 100mPa・s.
    Approx. 1 minute is required to measure samples with a viscosity of 10,000mPa・s.

    Rheological Properties

    Shear rate : 0.01 to 150s-1 (depending on the sample’s viscosity)

    The shear rate can be varied by changing the rotational speed of motor, flow curves can be determined.

    Suitable for Very Small Samples

    Sample volume required : 90μL

    Measurements of samples which are available in very small quantities can now be performed. During measurement, the samples are not contaminated.
    Samples can be used for other purposes after measurement.
    Required amount of sample is 300μL in standard specification. By using an optional small volume container, it is possible to measure with a minimum sample volume of 90μL.

    Versatile Measuring Container

    No cleaning required.

    Measurements are performed in a disposable sample container.
    No cleaning required – no cross contamination.

    Autoclave sterilization

    Ideal for samples which must be measured in a sterile environment such as proteins.

    Suitable for measurements under anaerobic conditions

    Sealed sample container. This allows to perform measurements in an inert-gas atmosphere.

    Applications

    Viscosity vs. temperature (silicon oil)

    Viscosity change at phase transition temp. 
    (liquid crystal)

    Curing process (epxoy resin)

    Viscosity vs. shear rate (lotion)

    Viscosity vs. Concentration (protein)

     

    Specifications

    Item Description
    Device name EMS Viscometer
    Electro Magnetically Spinning Viscometer
    Model name EMS-1000S
    Method of measurement Electro Magnetically Spinning Method (EMS)
    Viscosity measuring range 0.1~1,000mPa・s(Aluminium alloy spheres φ1.5mm:Option)
    0.1~100,000 mPa・s (Aluminium spheres φ2mm)
    10~1,000,000 mPa・s (Aluminium spheres φ4.7mm)
    100~100,000 mPa・s(Titanium spheres φ5mm:Option)
    Measurement accuracy repeatability RSD 3%(*1 according to KEM’s standard measuring conditions)
    accuracy ±10%(*1 according to KEM’s standard measuring conditions)
    Minimum sample amount 90μL(Small container and Aluminium spheres φ2mm:Option)
    300μL (Aluminium spheres φ2mm)
    700μL (Aluminium spheres φ4.7mm)
    700μL (Titanium spheres φ5mm, option)
    Temperature Range 0~200℃ (*2)
    0~50°C(Small container :Option)
    Stability ±0.1℃
    Motor rotation speed Range 500~1,000 rpm
    Stability ±3%
    Ambient conditions Temperature 10~30℃
    Humidity 85% RH max. (no condensation)
    Storage conditions Temperature -20~60℃
    Humidity 85% RH max. (no condensation)
    Power supply Main unit AC 200~240V±10% or AC 100~120V±10% 50/60Hz
    Control PC 100~240V±10% AC 50/60Hz (power adapter)
    Power consumption Main unit Approx.150W (Max 600W)
    Control PC Approx. 20W
    Dimensions Main unit 356 (W) × 347 (D) × 335 (H) mm
    Weight Main unit Approx. 24kg
    CE marking EMC EN61326-1
    LVD EN61010-1
    Laser safety EN60825-1
    Laser Wavelength 660 nm(Red)
    Beam
    Divergence
    Parallel to the Junction : 10°
    Perpendicular to the Junction : 17°
    Maximum output power 130mW in CW Operation

    (* 1) Repeatability is indicated by the relative standard deviation when the viscosity range is 10 to 1000mPa·s and the measurement is carried out 5 times continuously without changing the equipment conditions (sample, spherical probe and container combination).

    (* 2) When setting the preset temperature below room temperature, please prepare dry air for dew condensation prevention. Also, when setting the temperature below 10°C, keep the ambient temperature below 20°C.

Send your message to this supplier
  • From:
  • To:
    KYOTO ELECTRONICS MANUFACTURING (Shanghai) Co., LTD.
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service