Customized Cleanroom Air Shower Pass Box/Transfer Window/Delivery Window

Category:Cleanroom System > Purifying Engineering
Product Name:Customized Cleanroom Air Shower Pass Box/Transfer Window/Delivery Window
Price(USD):USD 100-400 per set
Company:QINGDAO WISE LINK INTERNATIONAL CO.,LTD

Basic Info
  • Factory Location: Shandong, China

    Main Sales Markets: North America,Central/South America,Western Europe,Eastern Europe,Australasia,Asia,Middle East,Africa

  • Packaging Information: standard exporting packing

  • Delivery Lead Time: 2 weeks

    Sample Provided: no

    Payment Terms: T/T

    The transfer window is a kind of auxiliary equipment for clean rooms, mainly used for the transfer of small items between clean areas and clean areas, clean areas and non-clean areas, in order to reduce the number of clean room doors, and reduce the pollution of clean rooms to a minimum. The transfer window is made of stainless steel plate, smooth and smooth. Two doors interlocking each other, effectively prevent cross-contamination, with electronic or mechanical interlocking device, and equipped with ultraviolet sterilization lamp.

    Model MRJH-1
    Function The function of the transfer window: it is a device for transferring items in the clean area to reduce the number of door openings; it is mainly used for the transfer of small items in clean rooms of different levels or the transfer of small items between clean areas and non-clean areas ; Prevent the low-level unclean air from entering the high-level clean room when transferring materials, which minimizes the pollution of the clean room.
    principle The transfer window can be divided into three types: electronic interlock transfer window, mechanical interlock transfer window and self-cleaning transfer window. According to the working principle, it can be divided into two types: air shower transfer window and ordinary transfer window. The interior of the transfer window is interlocked mechanically. When one door is opened, the other door cannot be opened, so the other door must be closed before the other door can be opened. In addition to this method, interlocking can also be achieved by using integrated circuits, electromagnetic locks, control panels, indicator lights, etc.
    Features The transfer window is divided into standard transfer window and clean transfer window (with empty self-cleaning device) according to the purpose;
    According to the form of door interlock, it can be divided into two types: mechanical interlock and electronic interlock;
    According to the material, the shell is divided into three types: color steel plate type, thin steel plate spray type (or paint type) and all stainless steel type;
    General-purpose size, special specifications can be produced upon request of users.

     

     

    The role of the transfer window:
    1. It is a device for transferring goods set up in the clean area to reduce the number of doors opened;
    2. Mainly used for the transfer of small items in different clean rooms or the transfer of small items between clean areas and unclean areas;
    3. Prevent low-level unclean air from entering the clean room when transferring materials, which reduces the pollution of the clean room to a low degree.

    Common types of transfer Windows

    1, mechanical:
    The transfer window has two internal and external sashes, among which there is a mechanical interlock, and this transfer window will bring polluted air into the clean room when it is opened.

    2. Airlock type (clean type) :
    There is clean air passing between the transfer window forms, that is, the fan and filter are installed in the transfer window, and the fan is started before opening the window to make the clean air pass.

    3, sterilization:
    For biological clean rooms, in order to prevent germs from being brought in, ultraviolet lamps are installed in the transfer window, after opening the window to put the object, close the window and turn on the ultraviolet lamp, irradiate the window for several minutes and then open the window to take out.

    4. Closed option:
    In order to make up for the defects that the mechanical transfer window will bring in polluted air, in addition to the use of airlock transfer window, closed ventilation can also be used.

    5. Laminar flow transfer window:
    Laminar flow transfer window is a kind of auxiliary equipment for clean room, mainly used to transfer small objects between clean room and unclean area or between clean rooms with different levels and different pressures. On the one hand, it plays the role of airlock to prevent the high pressure in the clean room from being relieved. On the other hand, the self-cleaning effect is realized in the re-transfer process, and the items entering the clean area are clean themselves to reduce cross-contamination caused by objects. Its blowing time absenteeism can be adjusted according to the manual switch, and the effect of self-purification and energy saving can be achieved.

Send your message to this supplier
  • From:
  • To:
    QINGDAO WISE LINK INTERNATIONAL CO.,LTD
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service