    Refrigerated heating circulator HRT-50℃~250℃

     

    Description

    Wide working temperature range with cooling and heating function, temperature range: -55~250℃.

     

    -55℃~250℃


    Description:
    The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the  tank temperature is limited to 60℃.
    The cycle is closed,there is no oil mist at high temperature and no water vapor at low temperature; Wide working temperature range of heat transfer oil; The entire circulation system without use of mechanical and electric valve.
    FEATURES:
    1.Wide working temperature range with cooling and heating function, temperature range: -55~250℃.
    2.With 2pcs of LED display controller, can show the setting temperature & actual value, and alarm value for overtemperature.
    3.Efficient fast, simple topping up liquid.
    4.Ensure fast cooling at high temperature and can acheive 250℃~-55℃ temperature control continuously.
    5.The cycle system is closed, there is no oil mist and water vapor happend, so as to assure the lab safety and heat transfer fluid lifetime.
    6.Use copeland brand compressor,circulation pump,stable performance and reliable quality.
    7.Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
    8.Use the same kind of heat conducting in the whole heating-cooling cycle when control heat conducting medium temperature.
    9.High-lift design and meet the long-distance transportation of heat conducting medium.

    Technical Parameters:

     

     

    Model

    HRT-25

    HRT-35

    HRT-50

    HRT-70

    HRT-100

    HRT-150

    Temperature range ℃

    -50℃250℃

    -50℃250℃

    -50℃250℃

    -50℃250℃

    -50℃250℃

    -50℃250℃

    Controller

    PID adaptive controller

    Temp. control

    Heat-conducting medium outlet temp. control

    Communication protocol

    MODBUS RTU Protocol, RS 485 Interface

    Temperature feedback

    Heat-conducting medium temperature feedback PT100         

    Temp. accuracy

    ±0.5℃

    ±0.5℃

    ±0.5℃

    ±0.5℃

    ±0.5℃

    ±0.5℃

    Heating power

    2500W

    3500W

    5500W

    7500W

    10000W

    15000W

    Cooling capacity

    250℃

    2000W

    3500W

    5500W

    7500W

    10000W

    15000W

    100℃

    2000W

    3500W

    5000W

    7000W

    10000W

    15000W

    20℃

    2000W

    3500W

    5000W

    7000W

    10000W

    15000W

    0℃

    1800W

    3000W

    5000W

    7000W

    10000W

    15000W

    -20℃

    850W

    1500W

    2850W

    4200W

    6000W

    11000W

    -40℃

    250W

    450W

    900W

    1500W

    2000W

    3750W

    Circulation pump

    Max20L/min

    2BAR

    Max35L/min

    2BAR

    Max35L/min

    2BAR

    Max50L/min

    2BAR

    Max50L/min

    2BAR

    Max50L/min

    2BAR

    Compressor

    France

    Copeland

    Copeland

    Copeland

    Copeland

    Copeland

    Evaporator

    Plate heat exchanger

    Plate heat exchanger

    Plate heat exchanger

    Plate heat exchanger

    Plate heat exchanger

    Plate heat exchanger

    Operation panel

    Display setting temperature and testing temperature; Touch key display

    Safety protection

    Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device,

    liquid low level protection, high temperature protection and temperature fault protection.

    Closed circulation system

    The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,

    pressure do not rise up when system is running. The system will supplement oil automatically at low temperature.

    Refrigerant

    R-404A

    R-404A

    R404A

    R404A

    R404A

    R404A

    Connection size

    DN-15

    DN20

    DN20

    DN20

    DN20

    DN-20

    Connection size

    (air-cooled)

    400*600*1050

    550*680*1450

    550*680*1450

    620*700*1450

    700*700*1750

    700*700*1750

    Weight (air-cooled)

    160kg

    185kg

    245kg

    285kg

    320kg

    360kg

    Power

    AC 220V 50HZ

    4.5kW (max)

    AC 380V 50HZ

    6.5kW (max)

    AC 380V 50HZ

    9kW (max)

    AC 380V 50HZ

    12.5kW (max)

    AC 380V 50HZ

    16.5kW (max)

    AC 380V 50HZ

    24kW (max)

    Case material

    Cold rolled steel

    Optional

    Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.

    Optional

    SUS304 case material

    Optional power

     220V 60HZ three-phase source, 440V480V 60HZ three-phase source  

     

Send your message to this supplier
  • From:
  • To:
    Wuxi Guanya Refrigeration Technology Co., Ltd. (LNEYA)
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service