50mm Spring pretightening chromatography column tube
1.Product Profile
30mm Spring pre-tightening chromatographic column is automatically filled column for high pressure preparative chromatography. The advantages are as below:
1)can be packed in a short time without secondary dismounting which can avoid column bed bouncing.
2)Piston and column bed are in contact all the time so the column bed would not collapse even after a long time use which can expand service life.
3)can fill one more chromatographic columns only using one set packing column machine .
4)Do not use electrical components, can be used in explosion proof area.
2. Have An Edge Over Competitors
1)Air cylinder replaces pneumatic hydraulic. All the pipes are pneumatic pipelines, expect the chromatographic column pipe internal pressure, others are not more than 8 bar, and more security. Secondly, only using compressed air as power source, the operating environment is more clean.
2)Pipe layout is more concise .Avoid all the hydraulic components which are used to turn air pressure to hydraulic pressure, more consistency, and the space is more larger and easy to operate.
3) Special design using sealing structure for the column bottom , tightening seal can be realized only buy hands.
4) Our exclusive design ensures high column efficiency.
5)Save reagent by short operating time.
The brief operation introduction of SAC
1)fix the packing column machine, and connect air pipeline .
2)Fix the filter plate and thread on the bottom of the chromatographic column tube.
3)Fix the chromatographic column tube into the packing column machine, then connect the two three-way ball valve.
4)Fix the piston peek pipeline and then fix the piston connecting rod, finaly fix the disc spring.
5)Homogenate , ultrasound.
6)Fix screwed conduit guide sleeve , then put nut and dummy wafer into screwed conduit.
7)Inject homogenate and wash the top of column tube.
8)Put the piston on the top of column tube.
9)Fall off air cylinder and press piston into the column tube.
10)Raise air cylinder, put screwed pipe into piston rod. Connect piston peek pipeline with two three-way ball valve.
11)Fall off screwed conduit by pressing air cylinder, press Emergency Stop Switch after liquid out of ball valve; switch ball valve and open EMS , fall off the air cylinder till finishing fix column tube.
12)Activate the chromatographic column tube through starting pump.
13)After the activation ,change the length of tabletting and force the nut together with tabletting .
14)Raise the air cylinder , dismantle chromatographic column .
15)Text chromatographic column .
50mm spring column product details
Column tube |
Inner diameter |
50mm |
length |
650mm |
|
The inner wall of processing |
Honing,polishing |
|
The inner wall surface roughness |
Ra≤0.4um
|
|
The maximum bed height |
300mm |
|
The minimum bed height |
50mm |
|
Maximum pressure |
260bar |
|
Filter plate |
Aperture |
2um |
Material |
316L powder sintering filter plate |
|
High pressure seals |
Material |
PTFE |
Structure |
Spring-loaded V-ring |
|
Piston |
Material |
316L |
Distribution type |
Sector |
|
Connection |
Import/Export |
1/16 or1/8 pipeline |